Water-infusion 
     Site: "Wetland restoration of Bruchlen/Kalimok Marshes"
water-infusion at point F
1.Test for a superficial layer
A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm;
height of the upper pipe end of the pipe of the terrain:0,79m
test after licking 20l. of water  
interval of lowering from and awaiting 30min. after that
measuring the upper end
  of the pipe /сm/ interval of lowering from
through 15sec. 0.0 measuring the upper end
  29.5   of the pipe /сm/
  45.0 through 1 min. 0.0
  59.0   3.5
  70.0   6.5
  79.0   8.8
  85.0   11.0
  90.0 through 2 min. 14.5
  93.0   18.4
  95.5   21.4
  97.8   24.3
  100.5   26.7
  101.5   28.9
  102 through 5 min. 34.2
  103.2   38.1
  42.3
2.A test in depth
measured from the terrain
depth of the boring:1,5m from the terrain with a diameter of 85mm
interval of lowering from
interval of lowering from measuring the upper end
measuring the upper end   of the pipe /сm/
  of the pipe /сm/ through 1 min. 86.3
through 15sec. 0.0   87.0
  28.0   88.5
  41.5   89.2
  56.0 through 2 min. 90.5
  65.0   91.5
  72.5   92.6
  77.5 through 5 min. 96.0
  80.0   99
  81.5   102
  82.5   105
  83.0   106.8
  84.0
  84.5 Sofia 11.07.2003
through 30sec. 85.5
Measured by:
eng.L.Lyubomirov