| Water-infusion | ||||||||||||
| Site: "Wetland restoration of Bruchlen/Kalimok Marshes" | ||||||||||||
| water-infusion at point E | ||||||||||||
| 1.Test for a superficial layer | ||||||||||||
| A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm; | ||||||||||||
| height of the upper pipe end of the pipe of the terrain:0,75m | ||||||||||||
| interval of | lowering from | interval of | lowering from | |||||||||
| measuring | the upper end | measuring | the upper end | |||||||||
| of the pipe /сm/ | of the pipe /сm/ | |||||||||||
| through 1 min. | 0.0 | through 10 min. | 3.0 | |||||||||
| 0.5 | 3.5 | |||||||||||
| 0.8 | 3.9 | |||||||||||
| through 5 min. | 1.6 | 4.4 | ||||||||||
| 2.0 | 4.8 | |||||||||||
| 2.4 | through 15 min. | 5.4 | ||||||||||
| 5.9 | ||||||||||||
| 2.A test in depth | ||||||||||||
| A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm; | ||||||||||||
| height of the upper pipe end of the pipe of the terrain:0,75m | ||||||||||||
| depth of the boring:1,5m from the terrain with a diameter of 85mm | ||||||||||||
| interval of | lowering from | interval of | lowering from | |||||||||
| measuring | the upper end | measuring | the upper end | |||||||||
| of the pipe /сm/ | of the pipe /сm/ | |||||||||||
| through 30sec. | 0.0 | through 2 min. | 169.5 | |||||||||
| 108.0 | 170.5 | |||||||||||
| 116.5 | through 5 min. | 172.0 | ||||||||||
| through 1 min. | 148.0 | 173.7 | ||||||||||
| 154.0 | 175.0 | |||||||||||
| 158.2 | 176.0 | |||||||||||
| 161.0 | ||||||||||||
| 162.8 | ||||||||||||
| through 2 min. | 164.9 | |||||||||||
| 166.7 | ||||||||||||
| 168.3 | ||||||||||||
| Sofia 10.07.2003 | ||||||||||||
| Measured by: | ||||||||||||
| eng.L.Lyubomirov | ||||||||||||