Water-infusion
     Site: "Wetland restoration of Bruchlen/Kalimok Marshes"
water-infusion at point C
1.Test for a superficial layer
A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm;
height of the upper pipe end of the pipe of the terrain:0,80m
interval of lowering from interval of lowering from
measuring the upper end measuring the upper end
  of the pipe /сm/   of the pipe /сm/
through 1 min. 0.0 through 5 min. 8.5
  2.0   10.0
  3.1   11.0
  4.0 through 10 min. 12.8
  4.8   14.0
  5.2   15.0
  5.9   16.2
  6.2   17.1
  6.8
  7.3
2.A test in depth
A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm;
height of the upper pipe end of the pipe of the terrain:0,68m
depth of the boring:1,5m from the terrain with a diameter of 85mm
interval of lowering from interval of lowering from
measuring the upper end measuring the upper end
  of the pipe /сm/   of the pipe /сm/
through 1 min. 0.0 through 1 min. 194.0
  120.0   196.0
  149.5   197.0
  160.0   197.5
  166.5   198.8
  171.0   199.2
  175.0
  179.0 Sofia 10.07.2003
  182.0
  185.0 Measured by:
  187.0 eng.L.Lyubomirov
  189.5
  191.5
  192.5