| Water-infusion | ||||||||||||
| Site: "Wetland restoration of Bruchlen/Kalimok Marshes" | ||||||||||||
| water-infusion at point C | ||||||||||||
| 1.Test for a superficial layer | ||||||||||||
| A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm; | ||||||||||||
| height of the upper pipe end of the pipe of the terrain:0,80m | ||||||||||||
| interval of | lowering from | interval of | lowering from | |||||||||
| measuring | the upper end | measuring | the upper end | |||||||||
| of the pipe /сm/ | of the pipe /сm/ | |||||||||||
| through 1 min. | 0.0 | through 5 min. | 8.5 | |||||||||
| 2.0 | 10.0 | |||||||||||
| 3.1 | 11.0 | |||||||||||
| 4.0 | through 10 min. | 12.8 | ||||||||||
| 4.8 | 14.0 | |||||||||||
| 5.2 | 15.0 | |||||||||||
| 5.9 | 16.2 | |||||||||||
| 6.2 | 17.1 | |||||||||||
| 6.8 | ||||||||||||
| 7.3 | ||||||||||||
| 2.A test in depth | ||||||||||||
| A PVC pipe is used with a length ot 1m and an internal diameter 85mm and an external one of 90mm; | ||||||||||||
| height of the upper pipe end of the pipe of the terrain:0,68m | ||||||||||||
| depth of the boring:1,5m from the terrain with a diameter of 85mm | ||||||||||||
| interval of | lowering from | interval of | lowering from | |||||||||
| measuring | the upper end | measuring | the upper end | |||||||||
| of the pipe /сm/ | of the pipe /сm/ | |||||||||||
| through 1 min. | 0.0 | through 1 min. | 194.0 | |||||||||
| 120.0 | 196.0 | |||||||||||
| 149.5 | 197.0 | |||||||||||
| 160.0 | 197.5 | |||||||||||
| 166.5 | 198.8 | |||||||||||
| 171.0 | 199.2 | |||||||||||
| 175.0 | ||||||||||||
| 179.0 | Sofia 10.07.2003 | |||||||||||
| 182.0 | ||||||||||||
| 185.0 | Measured by: | |||||||||||
| 187.0 | eng.L.Lyubomirov | |||||||||||
| 189.5 | ||||||||||||
| 191.5 | ||||||||||||
| 192.5 | ||||||||||||